FREQUENCY ADAPTIVE REPETITIVE CONTROL FOR WIND POWER APPLICATIONS USING GRID CONNECTED INVERTER

Ch. Cheranraj, P. Gajendrachary, B. Naresh, D. Prashanth, A. Yamuna

Abstract


This paper presents a novel repetitive control for alternative energy generation systems (WPGS), which achieves best performance in steady-state conditions due to a variable sampling /switching amount technique. The main objective of VSPT is to get an range| number} number of samples per grid amount, which solves the main drawback of RC, i.e., the loss of rejection to periodic disturbances due to grid frequency drift. The sampling/switching frequency is adjusted with a variable sampling period filter phase-locked loop, which additionally adds lustiness to the system due to its inherent tolerance to grid voltage Distortion and unbalances, and events such as frequency steps and faults. The control subsystems are represented, designed, and verified experimentally in a 10-kW WPGS.    The results obtained prove the accuracy of the proposed management even beneath severe disturbances, typical in grids with high WPGS penetration, providing ancillary functions to enhance reliableness and cut back operational prices.


Keywords


Grid-Tie Current-Controlled Three-Phase Inverters; Power Quality; Repetitive Control;

References


. C. Busada, S. Gomez Jorge, A. Leon, and J. Solsona, “Current controllerbased on reduced order generalized integrators for distributed generationsystems,” IEEE Trans. Ind. Electron., vol. 59, no. 7, pp. 2898–2909,Jul. 2012.

. F. Gonzalez-Espin, G. Garcera, I. Patrao, and E. Figueres, “An adaptivecontrol system for three-phase photovoltaic inverters working in a polluted and variable frequency electric grid,” IEEE Trans. Power Electron.,ol. 27, no. 10, pp. 4248–4261, Oct. 2012.

. E. ON Netz GmbH, “Grid connections regulations to high and extra high voltage,” Tech. Rep., Apr. 2006.

. J. Espi Huerta, J. Castello-Moreno, J. Fischer, and R. Garcia-Gil, “Asynchronous reference frame robust predictive current control for threephasegrid-connected inverters,” IEEE Trans. Ind. Electron., vol. 57, no. 3, pp. 954–962, Mar. 2010.

. V. Kaura and V. Blasko, “Operation of a phase locked loop system under distorted utility conditions,” IEEE Trans. Ind. Appl., vol. 33, no. 1,pp. 58–63, Jan./Feb. 1997.


Full Text: PDF

Refbacks

  • There are currently no refbacks.




Copyright © 2012 - 2023, All rights reserved.| ijitr.com

Creative Commons License
International Journal of Innovative Technology and Research is licensed under a Creative Commons Attribution 3.0 Unported License.Based on a work at IJITR , Permissions beyond the scope of this license may be available at http://creativecommons.org/licenses/by/3.0/deed.en_GB.